Franklin Fueling Systems · Manholes & Access Covers
FLEX-ING™ Composite Manways
38" and 42" composite access covers with raintight cam-lock options

Overview
Steel manhole covers are heavy, rust, and are a common cause of back injuries on forecourts. FLEX-ING™ composite manways replace them with a domed lid made from many layers of fiberglass bonded in premium resin and finished by hand. Franklin does not use wood or foam fillers. The lid is thicker where it matters, rising from 1" at the edge to 1¼" at the centre, which limits flex under wheels and extends service life.
The covers are engineered and tested to meet or exceed H20 and HS20 load ratings, meaning they are designed for axle loads of 32,000 or 16,000 pounds per set of dual wheels. The surface is slip resistant. A shallow handle recess and a chest-style handle with backer plate keep the wall thick at the point that takes the most impact. The 12 gauge steel skirt is powder coated.
Two diameters are offered, 38" and 42", each with spring-loaded handles as standard. Raintight versions can be fitted with cast Zn-Al-Mg slope-style cam locks that pull the lid down onto its gasket for a watertight seal, which keeps rainwater out of sumps. Franklin also makes R Line and MoreCore replacement lids that drop into existing OPW Conquistador™ and Morrison Bros. rings, plus handle and gasket kits. Apex uses these to upgrade covers on existing Lebanese stations without replacing the frames.
Key features
- Layered fiberglass and resin lid with no wood or foam filler
- Lid tapers from 1" to 1¼" at the centre for low deflection
- Engineered and tested to meet or exceed H20 and HS20
- Slip resistant surface
- Powder-coated 12 gauge skirt
- Spring-loaded handle standard on 38" and 42"
- Cast Zn-Al-Mg slope-style cam locks for raintight sealing
- Replacement lids for OPW Conquistador™ and Morrison Bros. rings
Specifications
FLEX-ING™ Composite Manways technical data
| Model | Diameter | Frame ID | Lid thickness | Skirt ID | Skirt height |
|---|---|---|---|---|---|
| 38" | 39" | 37" | 1" | 39.25" | 10.75" |
| 42" | 44" | 42" | 1" | 44.25" | 10.75" |
| Model | Description |
|---|---|
| 14U-3810 | 39" composite cover with 37" x 10" skirt |
| 14U-RT3810CL | 39" raintight composite cover with 37" x 10" skirt and cam locks |
| 14U-4210 | 44" composite cover with 42" x 10" steel skirt |
| 14U-RT4210CL | 44" raintight composite cover with 42" x 10" steel skirt and cam locks |
| 14U-39R | 39" R Line replacement lid |
| 14U-44R | 44" R Line replacement lid |
| 14U-39MOR | 39" MoreCore replacement lid |
| 14U-44MOR2 | 44" MoreCore replacement lid |
Figures from the manufacturer's published documentation. Confirm the final configuration with Apex at quotation stage.
Questions
FLEX-ING™ Composite Manways: common questions
- Can I replace an existing OPW or Morrison lid without changing the ring?
- Yes. Franklin's R Line lids replace OPW Conquistador lids and MoreCore lids replace Morrison Bros. lids. Measure the existing ring to pick the size.
- What makes a cover raintight?
- Raintight models seal on a gasket and can be fitted with cast Zn-Al-Mg slope-style cam locks that hold the lid down for a watertight seal.
Request a Quotation
Get a quotation for the Franklin Fueling Systems FLEX-ING™ Composite Manways.
Tell us the quantities and the site. Apex prepares every quotation for the project, then supplies, installs and services the equipment in Lebanon.
More in Manholes & Access Covers
All Manholes & Access Covers
FLEX-ING™ Fiberglass Manways
Wide-opening tank sump manway with a flared skirt that sheds water

EBW® Composite Manways
SAFE-LITE FRC covers from 12" to 42", life-tested under 20,000 lb loads

UPP® Composite Access Covers
EN124 rated, all-composite lid and frame in 900 mm and 1,060 mm openings

EBW® Cast Iron and Steel Manways
Metallic covers for fills, monitoring points and heavy-traffic sumps

EBW® Monitoring Wells
Complete groundwater monitoring well hardware from lid to filter wrap