Wolftank · DOPA® double-wall tank lining
DOPA® Lite
The quick route to a vacuum-monitored double-wall tank, with no sandblasting.

Overview
DOPA® Lite is Wolftank's simplest way to turn a tank into a double-wall tank. It is for tanks that are still in fair shape: air tight, with only slight corrosion, or double-wall tanks where only the outer wall has failed. Compared with DOPA® 6N it skips sandblasting, and Wolftank does not list structural reinforcement among its purposes. The focus is a sealed interstitial space that can be monitored.
The job is shorter as a result. Wolftank puts a DOPA® Lite conversion at 3 to 5 days for a 30 m³ tank, against 5 to 7 days for DOPA® 6N. No sandblasting or grit blasting is needed, no expensive equipment has to come to site, and the work uses no hot work and no flammable materials. The forecourt can stay open while the crew works.
The finished tank is a rehabilitated double-wall tank whose interstice is held under vacuum and watched 24/7 by a leak detection system. Wolftank rates the method for a lifetime extension of 20+ years and says the new surface also suits aggressive fuels such as biofuels, methanol and ethanol, solvents and even acetates. For station owners who need double-wall protection on a sound tank quickly, it is the quicker of the two DOPA® methods. Apex supplies and installs DOPA® Lite linings in Lebanon and can assess whether a tank qualifies.
Key features
- For air-tight tanks with slight corrosion, or double-wall tanks with a failed outer wall
- Double wall in 3 to 5 days for a 30 m³ tank
- No sandblasting or grit blasting required
- No expensive equipment needed on site
- No hot work and no flammable materials
- Vacuum interstitial space with 24/7 leak monitoring
- Lifetime extension of 20+ years
- Surface suitable for biofuels, methanol, ethanol, solvents and acetates
- Uninterrupted site operations
Specifications
DOPA® Lite technical data
| DOPA® Lite | DOPA® 6N (DOPA® double wall structural lining) | |
|---|---|---|
| Initial tank condition | Air tight, slight corrosion, failed outer wall of double wall tank | Leaking, highly corroded, with shape problems, failed double wall tanks (inner or outer wall) |
| Surface preparation | No sandblasting required | Sandblasting to SA 2.5 |
| Structural reinforcement | Not stated | Yes, structural reinforcement of the tank |
| Lifetime extension | 20+ years | 20+ years (up to 30 years on page 13) |
| Days to line a 30 m³ tank | 3-5 | 5-7 |
Figures from the manufacturer's published documentation. Confirm the final configuration with Apex at quotation stage.
Questions
DOPA® Lite: common questions
- Is my tank suitable for DOPA® Lite?
- Wolftank lists DOPA® Lite for tanks that are air tight with slight corrosion, and for double-wall tanks whose outer wall has failed. Leaking or badly corroded tanks need DOPA® 6N.
- How long does DOPA® Lite take?
- Wolftank estimates 3 to 5 days for a 30 m³ tank.
- Is the interstice monitored like DOPA® 6N?
- Yes. The tank gets a vacuum interstitial space that is monitored 24/7 by a leak detection system.
Request a Quotation
Get a quotation for the Wolftank DOPA® Lite.
Tell us the quantities and the site. Apex prepares every quotation for the project, then supplies, installs and services the equipment in Lebanon.